中文字幕av线,色必久久,日韩精品中文字幕在线播放,中文字幕日韩视频,中文字幕av88,国产老女人高潮大全,偷拍久久网

Welcome to Jiaozuo Libo Light Alloy Co., Ltd.

Aluminum alloy sacrificial anode

magnesium anode, zinc anode

Telephone:

0391-7588881 +8618739187123

Jiaozuo Libo Light Alloy Co., Ltd.

News

News

Contact

Phone:18739187123

hotline:0391-7588881

E-mail:970512272@qq.com

Address:Wuzhi County, Jiaozuo City, China

Industry News

Measuring method for cathodic protection

  • Author:Libo
  • Source:wm.wanka5151.com
  • Date:2021-06-11
  • Click:0

Current test: the middle distance of two wires welded at both ends is 30 meters.


Potential test: two lines of pipe, reference electrode wire.


Sliding reference method


This method is mainly used to measure the cathodic protection potential distribution of the outer wall of the bottom plate of large storage tanks. For a new storage tank, the sliding reference method is generally not used, but during the design period, a reference electrode is arranged on the center and radius of the tank bottom every 5-10m. Usually, the long-acting copper sulfate electrode or zinc reference electrode with packing is used, just like the near reference method, to measure the potential distribution of tank bottom. For the built tanks, the sliding reference method may be a feasible scheme.


Surface reference method


This method is a conventional method for measuring buried metal structures. The test point of this method is to place the reference electrode on the top of the underground metal structures and ensure a good electrical contact between the reference electrode and the soil. The reference electrode lead of the test wire leading from the metal structure to the ground is also connected to the high resistance voltmeter and the reading is taken directly. This method can be used for fixed-point measurements at the test pile or for long-distance closed-circuit measurements at the top of the pipe, where the measured data represent the pipe/ground potential at the reference electrode.


Nearly participation ratio method


In order to measure the pipe/ground potential more accurately and reduce the soil resistance pressure drop component as much as possible, the reference electrode can be placed as close as possible to the pipe surface under test. The measurement point of this method is to put the reference electrode as close as possible to the surface of the structure to be measured. If the measured surface has a good cover layer, the corresponding place of the reference electrode should be the iron dew point of the cover layer, otherwise it is not meaningful. For the hot oil pipeline, when using the near reference method, attention should be paid to the adverse effect of the thermal field of the pipeline on the reference electrode, which can be solved by pulling the auxiliary test piece out for a certain distance.


Current test: the middle distance of two wires welded at both ends is 30 meters.


Potential test: two lines of pipe, reference electrode wire.


Online
聯(lián)系方式

熱線電話

18739187123

上班時間

周一到周五

公司電話

0391-7588881

桦甸市| 分宜县| 太保市| 那坡县| 鄂州市| 五原县| 贡嘎县| 屯昌县| 石阡县| 凤台县| 黄平县| 界首市| 吴江市| 胶南市| 白沙| 锡林郭勒盟| 襄汾县| 山西省| 长岭县| 石河子市| 石狮市| 红桥区| 陆良县| 河池市| 太湖县| 玉林市| 灌云县| 扬中市| 分宜县| 平舆县| 五寨县| 临澧县| 安岳县| 锡林浩特市| 屯留县| 双辽市| 凤冈县| 刚察县| 平定县| 民勤县| 宜黄县|